Most Popular


Incredible!Automatic wire stripping machine makes your hands free.
That’s why more and more manufacturers choose automatic wire stripping machine? Let your hands free!The appears of automatic wire stripping ... ...



Full Digital Intelligent Terminal Crimping Machine Failure Elimination

Rated: , 0 Comments
Total hits: 811
Posted on: 10/21/17

Full Digital Intelligent Terminal Crimping Machine Failure Elimination

Failure 1: Stripping front opening length varies.
Reason a: Feeding wire wheel is too tight or relaxed;
Solution: use wheel trimming bar to adjust two wheels gap so as not to press the wire firmly or too relaxed to slip the wire.

Reason b: cutting and stripping knife cut too shallow or too deep;
Solution: use knife deep shallow adjust bar to move knife-edge to the appropriate location, in order not to hurt the copper wire and can smooth off the rubber.

Reason c: cutting and stripping knife abrade.
Solution: Replace the new cutting knife.

Failure 2: Crimping terminal exposed copper wire unevenly.

Reason and solutions:

a. Check whether gun-shaped arm phase conduit attached with wire together or not.
b. Check whether the knife edage is vertical to arm conduit or not.
c. Check the terminal machine auxiliary briquetting is loose or not.
d. Check the distance betweeen terminal crimping machine and automata is changed or not.

Failure 3: electronic wire cutting length inconsistent
Reason a: feeding wire wheel too tight or too loose;
Solution: use wheel trimming bar to adjust two wheels gap so as not to press the wire firmly or too relaxed to slip the wire.

Reason b: Straightener too tight or loose
Solution: Adjust straightener takes effective and sending wire smoothly.

Reason c: tangent knife edge is abraded.
Solution: replacement new knife.

Failure 4: the machine can not start running or running in stop.
Reason and solutions:
a. Check for current input (220V) and 6KG Pressure;
b. The total number to check the settings with or without arrive restart after a power failure, if any, get to reset;
c. Check whether the wire or a functioning parts stuck;
d. Check whether the terminal machine signal connection or power connection lead to the terminals of the machine is not pressing.