Incredible!Automatic wire stripping machine makes your hands free.
That’s why more and more manufacturers choose automatic wire stripping machine? Let your hands free!The appears of automatic wire stripping ... ...



Automatic terminal crimping machine failure reason and eliminations

Rated: , 0 Comments
Total hits: 823
Posted on: 10/21/17

Automatic terminal crimping machine failure reason and eliminations


1, failure: the length of the different stripping opening;

Reason a: the wire inlet wheel pressed too tight or loose;

Countermeasures: use wire roller fine-tune piece to adjust the gap of wire inlet wheels until the wire won’t be compressed flattened or too loosen slip.

Reason B: cutting knife cut too shallow or too deep;

Countermeasures: to adjust the depth of the cutting knife to adjust the blade to the appropriate location, so as not to damage the copper wire and smooth off the rubber.

Reason C: cut off knife wear or blade edge;

Countermeasures: replace the new cutting blade.

 

2, failure: crimped crimp exposes uneven copper wires;

Reasons and countermeasures:

A. check whether the gun type swing arm is attached to the wire;

B. check whether the edge of the terminal machine is relatively straight with the swing arm;

C. check terminal machine auxiliary block is loose;

D. check the distance between terminal machine and automatic machine has no change.

 

3, failure: the cutting length of the electronic wire is not consistent

Reason a: wire inlet wheel pressed too tight or too loose;

Countermeasures: use wire roller fine-tune piece to adjust the gap of wire inlet wheels until the wire won’t be compressed flattened or too loosen slip.

Reason B: straightening device is too tight or loose;

Countermeasures: adjust the straightening device can play a straightening role and can be sent out smoothly as a principle.

Reason C: tangent edge wear or knife edge;

Countermeasures: replace the new cutter.

 

4, failure: the machine can not start or stop operation;

Reasons and countermeasures:

A. check whether the current input (220V) and 6KG air pressure;

B. check whether or not the total number of settings to reach, if it reaches the settings, shut off and restart machine;

C. check for a wireless material or a running part stuck;

D. check whether the terminal machine is connected to the signal or the power supply is connected to the terminal machine.